Vedard Alarm Security Export Sales Company
Vedard Alarm Security Export Sales Company
News
Security Alarm Systems Technical Supports
Source: Vedard Security Alarm Systems
Date: 2015/12/09
KB-A1188 is LCD keypad programming Ademco Contact Security Alarm Control Panel. It has both wire telephone network and wireless GSM network for reliable alarm signal transmission.
KB-A1188 is designed for security service installing small business, store, shop security and protection. 6 wired zones and 6 wireless zones enable the easy installation of detectors.
KB-A1188 is sophistical designed with sound and light signal communication. Not only details of installing and programming the alarm system are written in our user’s manual, but also troubleshooting is written in the user’s manual.
Here is the troubleshooting for KB-A1188 and many are suitable for general security alarm systems as well.
Trouble 1:
When it connects with AC, the running indicator of alarm panel isn’t bright.
Cause 1:
Check whether the plug is input in the socket.
Solution 1:
Input the plug in the socket.
Cause 2:
Check the problem of AC socket.
Solution 2:
Change the new socket.
Trouble 2:
When you press the key of remote controller, the indicator of remote controller doesn’t turn on or the distance of remote controller is too short.
Cause:
The battery power of remote controller is not sufficient.
Solution:
Change the battery of remote controller.
Trouble 3:
The indicator of a wired zone is often bright.
Cause 1:
Wiring of detector is wrong or the contact has problem.
Solution 1:
Check the wiring of detector is connected correctly. Check the terminal screw of wiring is tightened.
Cause 2:
When the triggering way of zone is set to be end-line resistor, the end-line resistor such as 2.2K or 4.7K should be connected.
Solution:
Connect the end-line resistor as required to the zone ends.
Trouble 4:
The wireless zone reports that the battery power is low.
Cause:
The battery power of detector is low.
Solution:
Change the battery of the detector.
Trouble 5:
Wireless detector often alarms in mistake.
Cause:
The installation position of the detector doesn’t up to the standard of installation.
Solution:
Re-place the detector installation position.
Trouble 6:
When the alarm panel dials the alarm telephones, the alarm center failed communication.
Cause:
The type of this alarm telephone wasn’t defined.
Solution:
Program the alarm telephone type correctly.
Trouble 7:
When the telephone receives the alarm, you will hear a voice of disconnection between the alarm panel and the telephone.
Cause:
The telephone which connected with the alarm panel turns on the anti-theft dialing function.
Solution:
The anti-theft dialing function of telephone which is connected with the alarm panel should be closed.
Trouble 8:
When the alarm system is armed, the arm indicator is off and the alarm panel makes five sounds of “Di…Di…Di…Di…D”.
Cause 1:
One of the wired zone is in trouble.
Solution 1:
Check the wired zones.
Cause 2:
The user is not authorized to arm the alarm system.
Solution 2:
Authorize the user to arm the alarm system.
Trouble 9:
When arm is made successfully, the trouble zones bypass automatically.
Cause:
The function of forced arm is open.
Solution:
Close function of force arm.
Trouble 10:
3# and 4# remote controllers can’t be learned to arm/disarm and also hearing five sounds of “Di…Di…Di…Di…D”.
Cause:
Arm/disarm operation of 3# and 4# remote controllers are not open.
Solution:
Authorize arm type for 3# and 4# remote controllers.
Trouble 11:
Alarm phone is enrolled, but it doesn’t dial when alarm.
Cause:
You didn’t input *4 at the end of the alarm phone when enroll the phone number to the alarm panel.
Solution:
re-enroll the alarm phone number and add *4 at the end.
Trouble 12:
At disarm status, trigger the detector, the keypad buzzer sound for 2 seconds.
Cause:
The triggered zone is 24 hours zone or doorbell zone.
Trouble 13:
Every 20 seconds, the keypad will sound for 1 second.
Cause 1:
Telephone line error
Solution 1:
Check and confirm the telephone line is connected well.
Cause 2:
Wireless detector battery power is low
Solution 2:
Check and replace wireless detector battery
Cause 3:
GSM module error
Solution 3:
Check GSM module antenna, SIM card connection with alarm panel.
More News
China Security Exhibition 2019 Oct. 28th to 31st
Shopping mall and market interconnection security solution
Intelligent optical fiber perimeter security system
Garden solar alarm lamp
China Chemical plant explosion and Security Consideration
Fire and Explosion in Chemical Plant causes and prevention
Chemical plants fire escape methods and points for attention
Fire Alarm and automatic panel operation training
China Chemical plant explosion and Security Consideration
FIRE DETECTION & ALARM FOR PUBLIC BUILDING AND PREMISES
COMPLETE HOME SECURITY SYSTEM SELF-MONITORED
THEFT & BURGLAR ALARMS FOR HOME SECURITY
What to do with Fire alarm and How to recover alarm devices
How to install PIR and Door Contact for home security
7 causes for false alarm of fire detectors
PIR Passive Infrared Detector installing notice
Automatic fire alarm system terms of manual and automatic control
Is Burglar Alarm System useless?
6 home security solution for different budget and security levels
Electric Fire and Electric Socket
Security Service Network Alarm System upgrade
Explosion proof Fire Alarm Gas Detector Sounder Beacon
Solar Wireless PIR Detectors Features
Fire Alarm System Troubles Resolve Solutions
Fire Alarm Systems Maintenance and trouble shooting
How to avoid CO carbon monoxide poisoning
What is beam system and how does it work
Customers frequently asked questions about Solar Beam systems
How to clean Smoke Detector
Test Method and Notes for the Solar Powered Wireless Beams
Do not use water for these types fire extinguishing
How to disable Smoke Alarm temporarily?
Professional Security System installation standards
Home Security anti-theft knowledge and technology
How to escape from bus fire
How to use fire extinguishers
Flammable gas alarm installation and inspection
Addressable Fire Alarm System illustration
Building Fire Security System
Christmas Home Security Protection cautions
COMPLETE HOME SECURITY SYSTEM SELF-MONITORED
THEFT & BURGLAR ALARMS FOR HOME SECURITY
Wireless Fire Alarm System for commercial security
2017 China Security Fair News
Installing outdoor security cameras
Is Smart Home equal to App controlled Home
2017 China Public Security Exposition & Security Forum
Notice for wiring FC-7448 bus-line alarm system
How to install and debug FC-7448 Commercial Security Alarm System
2017 China Public Security Exposition
Combination of fingerprint lock and home security system
Cold Storage needs fire alarm system
Fire Security for garage, motor repair shop, parking area
FAS design notice
Photoelectric Beam Detection System Solution
How is sensor important for smart home
How to set up driveway alarm systems
Install intruder detector
Upgrade of PSTN network alarm service center
CMS server requirement and operation
meian tech wireless motion detector
Intrusion detector technology and development
intelligent security
Wireless fire alarm system
General Operation of Fire Alarm Control System
Addressable FACP MN300 Instruction
Alarm System Troubleshooting–Part 1 CMS
Alarm System Troubleshooting–Part 2 Alarm Control Panel
Alarm System Troubleshooting–Part 3 Detector
New technology security alarm server EAVS
Fire alarm system design
bus system security alarm technology
Fire Detectors types and selection
Exterior Security Protection
Home Incidents Prevention
Dangerous gas leakage Alarm Device Installation
Hotel Security Solution
Burglar Alarm System Installation Notes
Intelligent Community Security FAQ
Fire Indication on Alarm Control Panel
Fire Defighting System
Fire prevention and escape
Base Station Integrated Security Solution
Community Security Solution
October 25-28, 2016 China Security Exhibition
China Security Alarms Technology
Theft & Burglar Alarms for Home Security
Install Infrared Beams Detector
China Security Alarms Technology
Security System and Smart Home
Home Fire Prevention in Summer
Set up IP camera for home surveillance
Home Security Systems company Karassn cooperation
Pet immune Motion Detectors and the technology
How would you like to manage home security
Program Alarm Systems Solar Beam Detectors
Smoke Alarm types and connection
Question of Focus Security Alarm Systems
Security Service & DIY home security
Fire Alert Security Alarm Solution Signal Systems
Security Exhibition 2015 in Shenzhen China from 29th Oct.
Advanced Technology Burglar Alarm Systems
Install wireless door magnetic alarm sensor for rolling door
Fire guard read fire alarm manuals and test fire alarm systems before fire happening
Correct wiring Smoke Alarms for Fire Alarm systems
Carbon Monoxide danger
Questions for Solar-powered wireless infrared grating
Smoke Alarm Questions
Alarm system industry trend and alarm system installer job
Conventional Fire Alarm Security Solution
Perimeter Security Solution with Solar Beams
Reliable Wireless Alarm Systems
Smart Home & Secure Home
Flammable gas alarm installation and inspection
Program Alarm System and understand the terms
2014 Security China International Exhibition
Test Method and Notes for the Solar Powered Wireless Beams
Energy saving theft deterrent
Wireless Fire Alarm Solution For Hotel
Additional wireless detectors to existing alarm system
Home Alarm Security Service Development and the importance
Cheap or Quality China Alarms System
DIY alarms or Professional installed alarms
We help buyer buying China Alarm Security Systems
Alarm System Store for DIY without any consultant's advice
Cooperate with Alarm Systems Installers and Security Service
Digital Network Video Server alarm panel
Quick guide to program FC-7448 building security alarm panel
How to choose Motion Sensors from technology views
Advanced technique of intruder detectors
Integration of Security System
Wireless compare with Wired Alarm System